Field Name |
Data Description |
Test Name |
Epstein-Barr DNA (EBV) Quant. PCR |
Code |
EBV Amplified Probe. |
CPT Code |
87799 |
Last Modified |
1/19/2022 1:05:00 PM |
Test Name |
EBV AmpPrb. |
Synonyms |
Epstein Barr virus, quantitative, EBV viral load, DNA by PCR |
Patient Preparation |
|
Spec. Requirements |
Blood |
Tube |
Lavender |
Collection Volume |
2.0 mL |
Storage |
Refrigerate 7 days, Frozen 90 days |
Routine TAT |
|
STAT TAT |
N/A |
Days Test Performed |
|
Performed by BHS |
None |
See Availability |
|
Reference Lab |
LabCorp of America |
Reference Lab Code |
138230 Epstein-Barr DNA Quant, PCR |
Clinical Use |
This test is intended to be used for the quantitative detection of Epstein-Barr virus (EBV) DNA and as an aid in the diagnosis and management of EBV infections. |
Reference Range |
|
Critical Value |
|
|
Testing Sample Type |
Plasma, Frozen |
Min Lab Testing Volume |
0.5 mL |
Special Handling |
Collection:Collect specimen in lavender-top (EDTA) tube. Centrifuge specimen within 24 hours of collection. Remove plasma, transfer plasma to a screw-cap polypropylene transport tube, and freeze. Ship frozen (preferred). |
Lab Notes |
Quantitative range is 100 to 1,000,000 copies/mL |
Methodology |
PCR - Polymerase chain reaction |
Limitations |
Causes for Rejection:Quantity not sufficient for analysis; gross specimen contamination; specimen too old; leaking or broken tube; Received ambient |