Field Name |
Data Description |
Test Name |
Lactose Tolerance Test (Lactose Consumption Test) |
Code |
LACTOL |
CPT Code |
82951 |
Last Modified |
4/22/2014 |
Test Name |
LACTOSE TOLERANCE (3084) |
Synonyms |
|
Patient Preparation |
12 hour fast and remain fasting until test is complete |
Spec. Requirements |
Blood |
Tube |
Lt. Green or Gold |
Collection Volume |
3.0 mL Lt Green or 3.5 mL Gold |
Storage |
Ambient - 8 hours after centrifugation. |
Routine TAT |
2 hours |
STAT TAT |
|
Days Test Performed |
Daily |
Performed by BHS |
All Hospitals |
See Availability |
7 - 3 Shift |
Reference Lab |
N/A |
Reference Lab Code |
|
Clinical Use |
Used to evaluate lactose deficiency. |
Reference Range |
A peak rise of greater than or equal to 30 mg/dL in the blood glucose signifies normal activity.
A peak rise between 20 - 29 mg/dl in the blood glucose is inconclusive.
A peak rise of <20 mg/dl in the blood glucose strongly suggests lactose deficiency |
Critical Value |
|
Component |
Lactose |
Reference Range |
A peak rise of greater than or equal to 30 mg/dl in the blood glucose signifies normal activity.
A peak rise between 20 - 29 mg/dl in the blood glucose is inconclusive.
A peak rise of <20 mg/dl in the blood glucose strongly suggests lactose deficiency. |
Critical Value |
|
 |
|
Testing Sample Type |
Plasma or Serum |
Min Lab Testing Volume |
0.5 mL |
Special Handling |
|
Lab Notes |
Draw fasting specimen before administration of lactose. Draw glucose specimens 15 minutes, 30 minutes, 45 minutes, 60 minutes, 90 minutes, and 120 minutes after ingestion of lactose. |
Methodology |
Glucose Oxidase O2 Electrode |
Limitations |
|